OBJECTIVE: To evaluate a diagnostic flow chart applying medical thoracoscoy (MT), adenosine deaminase (ADA) and T-SPOT.TB in diagnosis of tuberculous pleural effusion (TPE) at a high TB burden country.

PATIENTS AND METHODS: 136 patients with pleural effusion (PE) were enrolled and divided into TPE and Non-TPE group. MT (histology), PE ADA and T-SPOT.TB were conducted on all patients. ROC analysis was performed for the best cut-off value of PE ADA in detection of TPE. The diagnostic flow chart applying MT, ADA and T-SPOT.TB was evaluated for improving the limitations of each diagnostic method.

RESULTS: ROC analysis showed that the best cut-off value of PE ADA was 30U/L. The sensitivity and specificity of these tests were calculated respectively to be: 71.4% (58.5%-81.6%) and 100% (95.4-100.0%) for MT, 92.9% (83.0-97.2%) and 68.8% (57.9-77.9%) for T-SPOT.TB, and 80.0% (69.6-88.1%) and 92.9% (82.7-98.0%) for PE ADA. The sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, positive predictive value and negative predictive value of the diagnostic flow chart were 96.4% (87.9-99.0%), 96.3% (89.6-98.7%), 25.714, 0.037, 97.4 and 94.9, respectively.

CONCLUSIONS: The diagnostic flow chart applying MT, ADA and T-SPOT.TB is an accurate and rapid diagnostic method in detection of TPE.

Free PDF Download

To cite this article

Y. He, W. Zhang, T. Huang, X. Wang, M. Wang
Evaluation of a diagnostic flow chart applying medical thoracoscopy, adenosine deaminase and T-SPOT.TB in diagnosis of tuberculous pleural effusion

Eur Rev Med Pharmacol Sci
Year: 2015
Vol. 19 - N. 19
Pages: 3563-3568